{"id":9822,"date":"2025-06-13T16:39:16","date_gmt":"2025-06-13T14:39:16","guid":{"rendered":"https:\/\/dev-site.se\/sutars.com\/product\/rk-kabel-ft-15-mm%c2%b2\/"},"modified":"2026-05-31T10:04:40","modified_gmt":"2026-05-31T08:04:40","slug":"rk-cable-ft-1-5-mm%c2%b2","status":"publish","type":"product","link":"https:\/\/sutars.com\/en\/product\/rk-cable-ft-1-5-mm%c2%b2\/","title":{"rendered":"RK cable ft 1.5 mm\u00b2"},"content":{"rendered":"<p>With its fine-stranded Class 5 construction, the cable is easy to handle and install \u2013 even in tight spaces. Each strand is tinned to protect against oxidation, a common cause of increased resistance, voltage drop, and, in the worst case, cable overheating or fire. The robust PVC insulation also provides solid protection against mechanical stress.<\/p>\n<p><strong>Key Benefits:<\/strong><\/p>\n<ul>\n<li>Tinned copper conductor \u2013 excellent corrosion resistance<\/li>\n<li>Highly flexible \u2013 ideal for tight installation spaces<\/li>\n<li>Compatible with both 12V and 230V systems<\/li>\n<li>Designed for harsh environments and year-round use<\/li>\n<li>Flame-retardant insulation for added safety<\/li>\n<li>Approved to EU\/ISO standards for use in boats<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<p><em>This cable is especially well-suited for use in boats, motorhomes, vehicles, and any application where safe, reliable wiring is essential \u2013 whether you\u2019re a professional installer or a dedicated DIY user.<\/em><\/p>\n","protected":false},"excerpt":{"rendered":"<p><strong>Tinned Copper Cable \u2013 Built for Vehicles, Boats, and Tough Installations<\/strong><\/p>\n<p class=\"p1\">Looking for a cable that\u2019s durable, flexible, and safe for vehicle or marine installations, as well as other demanding conditions?<br \/>\nThis high-quality tinned copper cable is a great choice for anyone who values reliability and safety in their electrical system.<\/p>\n","protected":false},"featured_media":14143,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false,"_seopress_robots_primary_cat":"none","_seopress_titles_title":"","_seopress_titles_desc":"","_seopress_robots_index":"","editor_notices":[]},"product_brand":[],"product_cat":[78,80],"product_tag":[],"class_list":{"0":"post-9822","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-cables","7":"product_cat-pvc-cable-single-conductor","8":"pa_farg-black","9":"pa_farg-blue","10":"pa_farg-brown","11":"pa_farg-green","12":"pa_farg-purple","13":"pa_farg-red","14":"pa_farg-white","15":"pa_farg-yellow","16":"pa_forpackning-m","17":"pa_forpackning-25-m","18":"pa_forpackning-50-m","19":"pa_forpackning-100-m","20":"pa_forpackning-minirulle-18-m","22":"first","23":"instock","24":"taxable","25":"shipping-taxable","26":"purchasable","27":"product-type-variable"},"acf":[],"meta_box":{"infotext":"<ul>\n<li>Cable area: 1.5 mm\u00b2<\/li>\n<li>Type: H07V-K FT<\/li>\n<li>Conductor material: Tinned copper, 30 x 0.238 mm \u00b10.008 mm<\/li>\n<li>Construction: Fine-stranded conductor according to VDE 0295 Class 5 \/ IEC 60228 Class 5<\/li>\n<li>Conductor resistance: 13.3 \u03a9\/km<\/li>\n<li>Insulation material: PVC TI1<\/li>\n<li>Minimum insulation thickness: 0.53 mm<\/li>\n<li>Average insulation thickness: 0.7 mm<\/li>\n<li>Outer diameter: approx. 2.95 mm \u00b10.4 mm<\/li>\n<li>Temperature rating (continuous): 70\u00b0C<\/li>\n<li>Operating temperature range: -25\u00b0C to +70\u00b0C<\/li>\n<li>Rated voltage (Uo\/U): 300\/500 V<\/li>\n<li>Minimum bending radius: 4 \u00d7 outer diameter<\/li>\n<li>Flame propagation rating: According to IEC 60332-1-2<\/li>\n<li>Standards compliance: IEC 60228.5 \/ HD 383.5 &amp; HD 50363.3<\/li>\n<li>Environmental compliance: RoHS 2011\/65\/EU<\/li>\n<li>Certification: CE approved<\/li>\n<li>Marine use: Approved for installation in boats and small craft in accordance with applicable EU and ISO standards<\/li>\n<li>Color options: Red, black, yellow, blue, green, brown, white and purple<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<p><a href=\"https:\/\/dev-site.se\/sutars.com\/en\/wp-content\/uploads\/sites\/6\/2025\/10\/Specifications-Skyllermarks-RK-Cable.png\"><img class=\"alignnone wp-image-14141 size-full\" src=\"https:\/\/sutars.com\/en\/wp-content\/uploads\/sites\/6\/2025\/10\/Specifications-Skyllermarks-RK-Cable.png\" alt=\"Table of Technical Specifications for Skyllermarks RK Cable Cable. Conductor size, number of strands, resistance at 20 \u00b0C, sheath thickness, outer diameter, and maximum current capacity.\" width=\"2051\" height=\"1247\" \/><\/a><\/p>\n","bild":false,"tips-rad":"","faq":[],"dokument":[],"produkttabell":[]},"_links":{"self":[{"href":"https:\/\/sutars.com\/en\/wp-json\/wp\/v2\/product\/9822","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/sutars.com\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/sutars.com\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/sutars.com\/en\/wp-json\/wp\/v2\/comments?post=9822"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/sutars.com\/en\/wp-json\/wp\/v2\/media\/14143"}],"wp:attachment":[{"href":"https:\/\/sutars.com\/en\/wp-json\/wp\/v2\/media?parent=9822"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/sutars.com\/en\/wp-json\/wp\/v2\/product_brand?post=9822"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/sutars.com\/en\/wp-json\/wp\/v2\/product_cat?post=9822"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/sutars.com\/en\/wp-json\/wp\/v2\/product_tag?post=9822"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}